Studio Matrx — Pro Zone / Space Planning & Design Tools
Standard Dimension Handbook
Code-referenced dimension guide for Indian homes — every measurement traced to its source. MBBL 2016 · IS 2064 · NSDC · Harmonised Guidelines.
Most-Used Dimensions
750 mm
Passage Min
Walking clearance
2700–3000 mm
Ceiling Height
Min–ideal
900–1200 mm
Kitchen Aisle
Min–ideal
800–914 mm
Countertop Height
IS 2064–NSDC
700–800 mm
Bathroom Door
IS 2064 min
900×900 min
Shower Area
1200×1200 ideal
1500–2000 mm
Wheelchair Turn
Min–comfortable
900–1050 mm
Switch Board
Universal standard
Code Minimums
MBBL 2016 / NBC — regulatory baseline for all residential design
Minimum
7.5 sqm / 2100 wide / 2750 ht
Ideal
9.5 sqm / 2400 wide / 2750 ht
Minimum area, width, and clear height for compliance
Minimum
9.5 sqm / 2400 wide / 2750 ht
Ideal
—
Applies to habitable rooms in plots above 50 sqm
Minimum
3.3 sqm / 1500 wide / 2750 ht
Ideal
4.5 sqm / 1500 wide
Minimum
4.5 sqm / 1500 wide / 2750 ht
Ideal
—
Minimum
3.0 sqm / 1400 wide / 2750 ht
Ideal
—
Minimum
1.2 sqm / 1000 wide / 2200 ht
Ideal
1.8 sqm / 1200 wide
Minimum
1.8 sqm / 1200 wide / 2200 ht
Ideal
—
Minimum
1.0 sqm / 900 wide / 2200 ht
Ideal
1.1 sqm / 900 wide
Minimum
1.8 sqm / 1000 wide / 2200 ht
Ideal
2.8 sqm / 1200 wide
Minimum
2.8 sqm / 1200 wide / 2200 ht
Ideal
—
Minimum
1000 mm
Ideal
1200 mm
Max / Luxury
1800 (double-loaded) mm
1800 mm for double-loaded residential corridors
Minimum
800 × 2000
Ideal
900 × 2200
Larger plot minimum; small-plot minimum is 800 mm width
Minimum
750 × 2000
Ideal
800 × 2100
Minimum
1000 mm
Ideal
1200 mm
General residential minimum per MBBL 2016
Minimum
250 tread / 190 riser
Ideal
280 tread / 175 riser
2200 mm minimum headroom above stairs
Minimum
450 mm
Ideal
600 mm
Above average road / site level
Minimum
3000 × 6000
Ideal
3300 × 6600
Minimum clear internal size
Minimum
Max 25% of covered area
Ideal
—
Minimum 1750 mm clear between loft floor and ceiling above
Source References
All dimensions are sourced from official Indian codes and standards
MOHUA / TCPO, Model Building Bye-Laws, 2016
BIS, IS 2064:1993 — Code of Practice for Selection, Installation and Maintenance of Sanitary Appliances
NSDC Cabinet Maker Modular Kitchen Participant Handbook
Ministry of Urban Development, Harmonised Guidelines and Space Standards for Barrier-Free Environment for Persons with Disabilities
MOHUA, General Building Requirements, National Building Code